Call us 24/7+86 18250705533
Welcome to the official website of Xingruijia Import and Export Co., Ltd!
Email:sales5@xrjdcs.com
[gt-link lang="en" label="English" widget_look="flags_name"] [gt-link lang="ar" label="ar" widget_look="flags_name"]

Advancing Endoscopy Technology with AC/DC Power Supplies and DC/DC Converters

Unlocking the Safety of Medical Equipment: Advancing Endoscopy Technology with AC/DC Power Supplies and DC/DC Converters

Navigating the complexities of endoscopy technology presents significant challenges. As invasive devices, endoscopes must adhere to strict leakage current regulations while fulfilling diverse power requirements, ranging from lighting to powering motors and cameras. To address these complexities, P-DUKE offers a comprehensive range of custom DC/DC converters designed to meet Type CF standards, ensuring that leakage current remains below 10µA.

Ensuring Electrical Safety in Medical Equipment

The electrical safety of medical devices is fundamentally achieved through two key protective measures:

  1. Isolation Barrier: The barrier between high-voltage AC or DC and the low-voltage electronic equipment connected to the patient. This topic is covered in our patient monitoring equipment case study.
  2. Limiting Leakage Current: The leakage current that could potentially flow through the patient’s body must be restricted. While industrial and household applications may allow leakage currents of up to 30mA, medical applications impose much stricter limits. Medical standards define three classes of equipment:
    • Type B (Body): Applications with no patient connection.
    • Type BF (Body Floating): Applications with patient connection.
    • Type CF (Cardiac Floating): Applications with patient connection, suitable for cardiac use.

Under normal operating conditions, leakage current must not exceed the following limits:

Leakage Current Type B Type BF Type CF
Earth Leakage Current 500µA 500µA 500µA
Enclosure Leakage Current 100µA 100µA 100µA
Patient Leakage Current 100µA 100µA 10µA

The primary source of leakage current is the EMI filter used on the primary side of AC/DC power supplies. P-DUKE offers a variety of AC/DC power supplies with built-in Class B EMI filters that meet the 100µA leakage current requirement for Type BF applications (see Figure 1). However, achieving the 10µA leakage current limit required for Type CF applications using only AC/DC power supplies would necessitate excessively large EMI filters.

Integrating AC/DC Power Supplies with DC/DC Converters

As a result, a combination of AC/DC power supplies and downstream DC/DC converters compatible with Type CF applications is often employed. Let’s explore a practical example.

Today, medical endoscopes are not only used for diagnostics but also for minimally invasive surgeries, incorporating modern optics, motors, soft robotics, and high-precision mechanics. These devices, used inside the human body, may come close to the heart and come into contact with blood. Therefore, they must comply with the 10µA leakage current limit for Type CF applications.

A customer sought to design a more compact video endoscope, equipped with an LED light source, a built-in camera in the endoscope’s head, and small motors that control the head’s movement.

How P-DUKE’s Power Solutions Enable Efficient Endoscope Power Systems

The system consists of a central processing unit (CPU) with a microprocessor, an interface to an external video processing unit, a hospital information system, and optional external storage devices. The total power consumption is approximately 26W.

The endoscope requires a 5V/20W power supply for the LED and camera, as well as a 12V/5W power supply for the small motor controlling the head’s movement via a Bowden cable.

The total system power consumption is approximately 44W. With P-DUKE’s full range of power converters, a highly flexible solution can be easily established (see Figure 2).

P-DUKE’s Medical Power Solutions: Enhancing Endoscopy Technology

The 65W MAD65 medical AC/DC power supply converts the AC power into a 12V bus voltage. It is a plug-and-play solution, with a built-in Class B EMI filter, and meets the medical requirements of 4000VAC reinforced isolation and 2xMOPP.

P-DUKE offers a comprehensive range of AC/DC power supplies from 15W to 450W, all of which comply with the 2xMOPP standard and have been updated to the latest medical safety certification EN60601-1 ED3.2.

Various power supply voltages for electronic devices are provided by P-DUKE’s downstream medical DC/DC converters. With leakage currents well below the 10µA limit, all these converters meet the Type CF standards.

For the microprocessor, a 5V/20W module is used, with additional 5W/10W DC/DC converters isolating all interfaces from the internal systems.

The same 5V/20W module powers the LED and camera in the endoscope, while a 12V/5W converter drives the motor. If a 3.3V power supply is needed, a small auxiliary converter can easily provide it.

Model MPM20-12S05 MPP10-12S05A/B MPK06-12S12A/B MPU01-12S3P3
DC/DC Converter
Input Range 9 – 18V 9 – 18V 9 – 18V 9.6 – 14.4V
Output 5V/20W 5V/10W 12V/5W 3.3V/1W
Isolation 5000VAC 5000VAC 5000VAC 5000VAC
Leakage Current 2.5µA max 2µA max 2µA max 2µA max
Dimensions/Package 1.6 x 1 inch DIP24 DIP24 SIP-9

P-DUKE’s medical power converter series makes it easy to design highly flexible solutions that meet all necessary safety requirements.

Redesign Considerations

The customer is now considering replacing the MAD65 AC/DC power supply with the new MAD50 50W series. The MAD50 occupies 25% less space (3” x 1.5”) than the MAD65 (3” x 2”), thereby freeing up space for other functions.

Model Today Redesign
MAD65US12C AC/DC Power Supply MAD50US12B
Vin 85 – 264 85 – 264
Output 12V/65W 12V/50W
Isolation 4000VAC 4000VAC
EMI Filter Class B Class B
Protection Class I Class II
Dimensions/Package 3 x 2 inch 3 x 1.5 inch

P-DUKE’s advanced medical power supply solutions continue to provide cutting-edge technology, ensuring the safety and efficiency of medical devices like endoscopes.

Main products include various PLCs, DCL servo systems, robot spare parts, frequency converters, etc
We have the discontinued spare parts you urgently need here,
Advantage spot goods, if you cannot inquire or buy, please contact us.
Beautiful price! Product guarantee, excellent value service, sufficient inventory,
Welcome to inquire, we will offer you a discounted price!
Sales Manager:Jinny
Email: sales5@xrjdcs.com
WhatsApp/Moblie: +86 18250705533
ABB IMDS114 - Bailey Infi 90 Modular System, Precision Control Solutions

LVM2120 3D Laser Profile Sensor: Achieving Precise Positioning for Automated Wood Cutting

The domestic market sees a substantial demand for wood applications.

With growing attention to panel processing quality, the wood processing industry is transitioning to large-scale mechanized and automated production. Traditional methods of wood positioning during processing or cutting rely on mechanical clamps, which often provide only rough positioning. This low precision can result in discrepancies between the processed or cut sections and the reference position, adversely affecting the quality of the wood panels.

Solution

To address the issue of wood positioning accuracy, customers are leveraging the high-precision LVM2120 3D Laser Profile Sensor from Elco. By using the sensor’s profile mode, precise positioning of wood panels is achievable. Additionally, the ultra-short measurement time ensures compatibility with the fast-paced production lines.

Equipment Specifications

  • Model: LVM2120
  • Profile Points: 1456
  • Installation Distance: 52 mm
  • Measurement Range: 26 mm
  • Field of View: 19–23 mm
  • Laser Wavelength: 405 nm

Detection Principle

The line laser 3D profile sensor is installed directly above the wood panel. The sensor remains stationary while detecting panels as they arrive at the detection station. Upon receiving a trigger signal, the sensor begins positioning the wood panel. The detection data is transmitted to a PLC, which then directs a servo motor to accurately position the wood panel.

Detection Process

  1. The wood panel is transported to the detection station via a conveyor, where mechanical clamps provide rough positioning.
  2. Once rough positioning is complete and the panel is within the detection range of the laser profile sensor, the sensor activates for precise laser detection.
  3. The sensor captures and transmits deviation data between the panel’s intended processing or cutting position and the reference position to the PLC.
  4. The PLC, upon receiving the precision positioning coordinates, adjusts the panel’s position using the servo motor, ensuring the panel is perfectly aligned for processing or cutting.

Detection Tools

The profile position tool employed by the system can automatically identify edge corner features of the wood panel and output XZ coordinates. This enables accurate positioning calculations, with a maximum precision of up to 20 µm.

Main products include various PLCs, DCL servo systems, robot spare parts, frequency converters, etc
We have the discontinued spare parts you urgently need here,
Advantage spot goods, if you cannot inquire or buy, please contact us.
Beautiful price! Product guarantee, excellent value service, sufficient inventory,
Welcome to inquire, we will offer you a discounted price!
Sales Manager:Jinny
Email: sales5@xrjdcs.com
WhatsApp/Moblie: +86 18250705533

Search for products

Back to Top
Product has been added to your cart
phone: +86 18250705533
to whats
+8618250705533
to whats
+8618250705533
email: sales5@xrjdcs.com